Electrical insulation plays a critical role in the safe and reliable operation of high-voltage electrical equipment. Over time, insulation systems can develop internal defects, air voids, surface contamination, and other weaknesses that may lead to partial discharge activity. If left undetected, these defects can gradually damage insulation and increase the risk of equipment failure.

Lax Energy Solutions Pvt Ltd provides advanced partial discharge measurement and testing solutions to help industries identify insulation-related issues and assess the condition of critical electrical assets. Using advanced diagnostic equipment and suitable measurement techniques, we support partial discharge testing for power transformers, switchgear, cables, and Gas Insulated Switchgear (GIS).

What Is Partial Discharge in Transformers?

Partial discharge (PD) is a localized electrical discharge that partially bridges the insulation between conductors. Unlike a complete electrical breakdown, partial discharge does not immediately create a complete connection between two conductors. However, repeated discharge activity can gradually deteriorate the surrounding insulation.

Partial Discharge Measurement and Testing Services

Lax Energy Solutions supports partial discharge measurement through advanced electrical and acoustic diagnostic equipment. Our testing solutions are suitable for evaluating insulation conditions across different types of high-voltage assets.

1. Partial Discharge Test on Transformer

Transformers are critical components of electrical transmission and distribution networks. Insulation defects within transformer windings, bushings, and other insulation structures can lead to partial discharge activity. Our partial discharge test on transformer applications helps identify discharge activity and assess the condition of transformer insulation.

The testing process can help with:

  • Detecting internal insulation defects.
  • Identifying potential discharge activity.
  • Assessing transformer insulation conditions.
  • Supporting transformer condition assessment.
  • Planning preventive and condition-based maintenance.

Partial discharge testing can be performed using suitable online or offline measurement techniques depending on the transformer design, operating conditions, and diagnostic requirements.

2. Partial Discharge Testing for Switchgear

Medium-voltage and high-voltage switchgear systems depend on reliable insulation to maintain safe electrical operation. Insulation deterioration, surface contamination, loose connections, and manufacturing defects can contribute to partial discharge activity. Partial discharge testing helps identify potential insulation problems in switchgear components before they develop into more serious electrical faults. The assessment supports equipment condition monitoring, maintenance planning, and improved operational reliability.

3. Partial Discharge Testing for Power Cables

Power cables are exposed to electrical, thermal, and environmental stresses throughout their service life. Insulation defects, ageing, and accessory-related issues can contribute to partial discharge activity. A partial discharge test helps assess the insulation condition of cable systems and identify potential discharge sources. These measurements can support cable condition assessment, maintenance planning, and decisions regarding further inspection or corrective action.

4. Partial Discharge Testing for GIS

Gas Insulated Switchgear (GIS) uses gas-insulated enclosures to provide compact and reliable high-voltage electrical distribution. Defects such as metallic particles, protrusions, insulation imperfections, and surface contamination may contribute to partial discharge activity within GIS equipment. Specialized partial discharge measurement techniques, including UHF-based detection, can help identify discharge activity and support insulation condition assessment.

Online vs Offline Partial Discharge Measurement

Online partial discharge measurement is performed while electrical equipment remains energized under operating conditions. It helps assess discharge activity under actual operating voltage and load conditions. Key benefits include of Online Partial Discharge Measurement & Offline Partial Discharge Measurement.

Advanced Partial Discharge Analyzer and Testing Equipment

Accurate partial discharge measurement requires suitable diagnostic instruments, sensors, and measurement configurations. Lax Energy Solutions uses specialized equipment to support partial discharge detection, measurement, and localization applications.

Our available equipment includes:

Portable electrical testing equipment for power system testing and diagnostics

OMICRON PDL650

Acoustic Partial Discharge Localization

The OMICRON PDL 650 is a multichannel acoustic emission system designed to detect and localize transformer-related faults.

Using piezoelectric sensors, it supports the detection and localization of acoustic signals associated with partial discharge, thermal, and arcing faults.

OMICRON electrical testing equipment for transformer condition assessment

Omicron MPD 600

PD Measurement System

The OMICRON MPD 600 is a partial discharge measurement system used for insulation diagnostics across high-voltage electrical assets.

It supports partial discharge measurement applications involving transformers, switchgear, cables, and GIS.

Portable power system testing equipment for electrical diagnostics

TECHIMP – AQUILA

PD MEASUREMENT HF & UHF METHOD

TECHIMP AQUILA supports online and offline partial discharge measurement using high-frequency (HF) and ultra-high-frequency (UHF) techniques.

It helps identify insulation-related discharge activity in transformers, switchgear, cables, and GIS equipment.

Portable electrical testing equipment for power system diagnostics

TECHIMP – MICRO AQUILA

Compact Partial Discharge Detection

TECHIMP MICRO AQUILA is a compact partial discharge detection solution designed for applications involving transformers, switchgear, cables, and GIS.

It supports online partial discharge measurement and UHF-based detection up to 3.0 GHz.

Why Is Partial Discharge Testing Important?

Partial discharge testing provides valuable information about the condition of electrical insulation systems. Detecting abnormal discharge activity can help organizations investigate potential defects before they develop into more serious equipment problems.
The major benefits include:

1. Early Detection of Insulation Defects

Partial discharge measurement helps identify localized insulation defects that may not be visible through routine visual inspection.

2. Improved Equipment Reliability

Understanding discharge activity helps maintenance teams assess the condition of critical electrical equipment and take appropriate action.

3. Reduced Risk of Unexpected Failures

Identifying abnormal discharge activity can support timely investigation and maintenance planning, helping reduce the risk of unexpected equipment breakdowns.

4. Better Maintenance Planning

PD test results provide useful diagnostic information that can support condition-based maintenance decisions.

5. Extended Asset Service Life

Monitoring insulation conditions and addressing developing defects can help organizations manage equipment deterioration and support long-term asset reliability.

Our Approach to Partial Discharge Measurement

At Lax Energy Solutions, partial discharge measurement is approached through suitable testing equipment, measurement techniques, and asset-specific diagnostic requirements.

Our general testing approach includes:

Understanding Equipment Requirements

Reviewing the equipment type, voltage class, operating conditions, and testing objectives.

Selecting the Measurement Technique

Choosing suitable electrical, HF, UHF, or acoustic measurement methods based on the asset and application.

Sensor and Instrument Setup

Arranging the required measurement instruments and sensors according to the testing configuration.

Signal Acquisition

Capturing and evaluating signals associated with partial discharge activity.

Diagnostic Assessment

Reviewing measurement patterns and identifying indications that may require further investigation.

Maintenance Recommendations

Supporting informed decisions regarding additional testing, inspection, or maintenance.

Frequently Asked Questions (FAQs)

What is partial discharge measurement?

Partial discharge measurement is a diagnostic process used to detect and evaluate localized electrical discharges occurring within or around insulation systems. It helps assess the insulation condition of high-voltage equipment such as transformers, cables, switchgear, and GIS.

A partial discharge test is an electrical diagnostic test used to identify and assess discharge activity in insulation systems. It helps detect potential insulation defects and evaluate the condition of high-voltage electrical equipment.

A partial discharge test on a transformer helps identify localized insulation defects that may contribute to insulation deterioration. It provides useful information for transformer condition assessment, maintenance planning, and reliability management.

Partial discharge measurement uses specialized instruments and sensors, including coupling capacitors, measuring impedance, HFCT sensors, UHF sensors, and acoustic emission sensors. Equipment selection depends on the asset and measurement technique.

A partial discharge analyzer is a diagnostic instrument used to detect, measure, and analyze electrical signals associated with partial discharge activity. It helps engineers evaluate insulation conditions and investigate potential defects.

Send Us a Message

Please enable JavaScript in your browser to complete this form.